The SB 410 inspection report rules took effect on January 1, 2026. They change what a condo association’s balcony inspection report must contain. As a result, boards now get a clear summary of their building’s condition on page one. This guide explains each requirement and what your board should check.

For a full overview of the law, see our SB 410 Law guide.

Why SB 410 changed the inspection report

SB 326 already required condo associations to inspect their balconies, decks, stairs and walkways every nine years. However, it did not say how the report should summarize the results. In practice, reports varied widely from one inspector to the next.

SB 410 fixes that. Governor Newsom signed it on October 10, 2025, as Chapter 516 of the 2025 statutes. It amended Civil Code section 5551 to set a standard first page for every report.

The 7-item first page of an SB 410 inspection report

Under SB 410, the first page of every inspection report must list:

  1. The date of the inspection
  2. The total number of units in the condominium project
  3. How many of those units have exterior elevated elements
  4. The total number of exterior elevated elements in the project
  5. How many elements the inspector actually inspected
  6. How many inspected elements pose an immediate threat to safety, and how many units they affect
  7. A certification that the inspector visually inspected a statistically significant sample

Together, these numbers let a board, an owner or a buyer judge the building at a glance from the SB 410 inspection report.

What the rest of the SB 410 inspection report covers

In addition to the first page, the report must still include the core findings from SB 326:

  • The load-bearing parts and waterproofing that make up each element
  • Their current condition, including any immediate safety threat
  • Their expected performance and remaining useful life
  • Recommended repairs or replacements

Who prepares and signs the report

Only a licensed structural engineer, civil engineer or architect can prepare an SB 410 inspection report. The inspector then signs or stamps the report and presents it to the board. After that, the report becomes part of the association’s reserve study.

What “statistically significant sample” means

The inspector does not have to check every balcony. Instead, they inspect enough units to be 95 percent confident in the results, with a margin of error of 5 percent or less. The inspector also makes a random list of every element first, so later inspections pick up where the last one stopped.

When an element is unsafe

If an element poses an immediate threat, the inspector sends the report to the association right away. They also send it to local code enforcement within 15 days. The association must then block access until the local agency inspects and approves the repairs.

How long to keep the SB 410 inspection report

The association must keep every report for two inspection cycles. Because of SB 410, the reports also count as association records, so members can ask to review them. In addition, sellers must give buyers a copy of the latest report. Read more in our guide to SB 410 disclosure requirements.

Checklist for HOA boards

  • Confirm your latest SB 410 inspection report has the 7-item first page.
  • Check that the inspector is a licensed structural or civil engineer or architect.
  • Make sure the report is in your reserve study.
  • Store reports so members and sellers can get copies quickly.

Source: SB 410 chaptered text.

Get an SB 410-ready inspection report

South Coast Deck Inspections prepares inspection reports that meet SB 410 for condo associations across Southern California. Request a proposal or call 657-707-9127.